Skip Navigation
Skip to contents

ACC : Acute and Critical Care

OPEN ACCESS
SEARCH
Search

Author index

Page Path
HOME > Issue > Author index
Search
Se Joong Kim 1 Article
Thoracic Surgery
A Closed-Suction Catheter with a Pressure Valve Can Reduce Tracheal Mucosal Injury in Intubated Patients
Jin Heon Jeong, Sung Jin Nam, Young Jae Cho, Yeon Joo Lee, Se Joong Kim, In Ae Song, Sang Heon Park, Young Tae Jeon
Korean J Crit Care Med. 2014;29(1):7-12.   Published online February 28, 2014
DOI: https://doi.org/10.4266/kjccm.2014.29.1.7
  • 7,342 View
  • 158 Download
  • 2 Crossref
AbstractAbstract PDF
Background
Endotracheal suctioning is associated with complications that include bleeding, infection, hypoxemia, cardiovascular instability, and tracheal mucosal injury. Recently, a closed-suction catheter with a pressure valve (Acetrachcare, AceMedical Co., Republic of Korea) was developed. We hypothesized that this new catheter might reduce tracheal mucosal injury compared to a conventional closed-suction catheter (Trachcare, Kimberly-balla RD, USA).
Methods
This prospective, randomized study enrolled medical and surgical patients who required mechanical ventilation for more than 48 hours. Patients were randomized into two groups: one group was suctioned with the conventional closed-suction catheter (CCC) and the other group was suctioned with the closed-suction catheter with pressure valve (CCPV). Bronchoscopy was performed 48 hours later, and the severity of tracheal mucosal injury was graded on a 5-point scale, as follows: 0 = normal; 1 = erythema or edema; 2 = erosion; 3 = hemorrhage; and 4 = ulceration or necrosis.
Results
A total of 76 patients (37 with CCPV and 39 with CCC) were included. There were no significant differences between the groups regarding demographic characteristics, changes in hemodynamic parameters during suction, incidence of pneumonia, length of intensive care unit (ICU) stay, or ICU mortality. On bronchoscopic evaluation, the use of the CCPV led to a significant decrease in tracheal mucosal injury (median tracheal mucosal injury grade 1 [IQR 0-1] vs. 2 [IQR 1-3], p = 0.001).
Conclusions
We conclude that the novel closed-suction catheter with pressure valve may reduce tracheal mucosal injury compared to conventional catheters.

Citations

Citations to this article as recorded by  
  • “Study on Device System to Reduce Tracheal Mucosal Injury in Intubation Patients” [ASME Journal of Medical Devices, 2022, 16(3), p. 031006; DOI: 10.1115/1.4054334]

    Journal of Medical Devices.2022;[Epub]     CrossRef
  • Efficacy of the Closed Suction Applied To Patients In Intensive Care Units with Different Techniques: A Nonrandomized Controlled Trial
    Zuhal GÜLSOY, Şerife KARAGÖZOĞLU
    Cumhuriyet Medical Journal.2020;[Epub]     CrossRef

ACC : Acute and Critical Care